{"id":323,"date":"2021-08-27T11:34:33","date_gmt":"2021-08-27T11:34:33","guid":{"rendered":"http:\/\/dummy.xtemos.com\/woodmart2\/elementor\/?post_type=product&#038;p=323"},"modified":"2024-10-21T20:52:13","modified_gmt":"2024-10-21T20:52:13","slug":"fan-coil-units-for-chiller-air-conditioner-hydronic-heating-cooling-ductless","status":"publish","type":"product","link":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/product\/fan-coil-units-for-chiller-air-conditioner-hydronic-heating-cooling-ductless\/","title":{"rendered":"Fan Coil Units For Chiller Air Conditioner &#038; Hydronic Heating &#038; Cooling &#8211; Ductless"},"content":{"rendered":"<h2>Ultra High Efficiency Fan Coil Units w\/ DC Inverter Fan Motors<\/h2>\n<p style=\"font-weight: 400;\">DC-Inverter fan motors run more efficiently and use less power than regular fan motors. Additionally, they are far quieter than a standard fan unit, you can hardly hear them running. And using a hermetically sealed fan motor means years of trouble free service because dust, salts, acids, and moisture cannot get inside. Did we mention more efficient? DC-Inverter fan motors use up to 75% less electricity to do the same job. Chiltrix Ultra-Slim DC-Inverter CXI FCUs are 110-130V 60Hz.<\/p>\n<h2>Chiltrix DC Inverter Fan Coil Units<\/h2>\n<table style=\"font-weight: 400;\">\n<tbody>\n<tr>\n<td width=\"47\">Chiltrix<\/td>\n<td width=\"44\">Cooling<\/td>\n<td width=\"47\">Heating<\/td>\n<td width=\"34\">Water<\/td>\n<td width=\"49\">Head<\/td>\n<td width=\"46\">Air CFM<\/td>\n<td width=\"29\">dB<\/td>\n<td width=\"25\">dB<\/td>\n<td width=\"41\">Power<\/td>\n<td width=\"88\">Power<\/td>\n<td width=\"111\">Net<\/td>\n<td width=\"87\">Shipping<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>BTU<\/td>\n<td>BTU<\/td>\n<td>GPM<\/td>\n<td>Loss (Ft.)<\/td>\n<td>Volume<\/td>\n<td>High<\/td>\n<td>Low<\/td>\n<td>Watts<br \/>\nHigh<\/td>\n<td>Supply<\/td>\n<td>Dimensions Inches<\/td>\n<td>Dimensions Inches<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>CXI120<\/td>\n<td>11,877<\/td>\n<td>9,733*<\/td>\n<td>2.5<\/td>\n<td>9.3<\/td>\n<td>340<\/td>\n<td>39<\/td>\n<td>28<\/td>\n<td>22<\/td>\n<td>115v 50\/60Hz<\/td>\n<td>51.2W x 5.1D x 26.4H<\/td>\n<td>52.8W x 7,1D x 28.7H<\/td>\n<\/tr>\n<tr>\n<td>CXI85<\/td>\n<td>8,498<\/td>\n<td>7,800*<\/td>\n<td>1.8<\/td>\n<td>9.2<\/td>\n<td>270<\/td>\n<td>37<\/td>\n<td>28<\/td>\n<td>21<\/td>\n<td>115v 50\/60Hz<\/td>\n<td>43.3W x 51.D x 26.4H<\/td>\n<td>44.9W x 7.1D x 28.7H<\/td>\n<\/tr>\n<tr>\n<td>CXI65<\/td>\n<td>6,451<\/td>\n<td>5,667*<\/td>\n<td>1.3<\/td>\n<td>4.4<\/td>\n<td>188<\/td>\n<td>32<\/td>\n<td>27<\/td>\n<td>18<\/td>\n<td>115v 50\/60Hz<\/td>\n<td>35.4W x 5.1D x 26.4H<\/td>\n<td>37.0W x 7.1D x 28.7H<\/td>\n<\/tr>\n<tr>\n<td>CXI34<\/td>\n<td>3,379<\/td>\n<td>3,013*<\/td>\n<td>1.2<\/td>\n<td>3.6<\/td>\n<td>94<\/td>\n<td>30<\/td>\n<td>24<\/td>\n<td>14<\/td>\n<td>115v 60Hz<\/td>\n<td>27.6W x 5.1D x 26.4H<\/td>\n<td>29.1W x 7.1D x 28.7H<\/td>\n<\/tr>\n<tr>\n<td>HW72<strong><br \/>\nExport Only<\/strong><\/td>\n<td>7,200<\/td>\n<td>6,640<\/td>\n<td>1.9<\/td>\n<td>5.1<\/td>\n<td>512<\/td>\n<td>46<\/td>\n<td>35<\/td>\n<td>40<\/td>\n<td>220 50\/60Hz<\/td>\n<td>31W x 9D x\u00a0 11H<\/td>\n<td>36W x 15D x 11H<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: 400;\">*CXI values listed are at Chiltrix normal temp of EWT 104F and vary based on configuration, please refer to<a href=\"https:\/\/www.chiltrix.com\/documents\/CXI-capacity-test.pdf\">\u00a0FCU capacity test data<\/a>\u00a0or contact us for more details.<\/p>\n<p style=\"font-weight: 400;\">Internal water volumes of CXI:\u00a0CXI-34=1.03L ,CXI-65=1.94L, CXI-85=2.86L, CXI-120=3.79L<\/p>\n<p>&nbsp;<\/p>\n<p style=\"font-weight: 400;\"><a href=\"https:\/\/www.chiltrix.com\/documents\/FCU-fan-coils.pdf\">See Ductless Fan Coil Specifications Sheet<\/a>\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0<a href=\"https:\/\/www.chiltrix.com\/documents\/Chiltrix-FirstCo-VMB-Specifications.pdf\"><u>See Ducted Hydronic Air Handler Specifications Sheet<\/u><\/a><\/p>\n<p><a href=\"https:\/\/www.chiltrix.com\/fan-coil-units-pix.html\"><u>See Pictures of installed CXI fan coil units<\/u><\/a><\/p>\n<p style=\"font-weight: 400;\">The Chiltrix CXI-series FCUs are the thinnest and quietest ductless chiller fan coil units available. They also use far less electricity to operate than any standard fan coil unit. The HW series is a standard high wall design of standard efficiency. The Chiltrix CX-series chiller heat pump units can work with\u00a0nearly any brand of fan coil unit, ducted or ductless, as well as hydronic in-floor systems.<\/p>\n<p style=\"font-weight: 400;\"><strong>Central Ducted Hydronic Systems:<\/strong><\/p>\n<p style=\"font-weight: 400;\">Ducted forced air systems are less efficient than ductless fan coil units due to static pressure drop and duct thermal loss. Ducted systems require a centralized thermostat,and cannot take advantage of individual zones in each room like a ductless system. In new construction, or when adding air conditioning to a building that has no current duct system, the installed cost of a ductless system will be about the same, or less than, installing with a duct system. However, if a central ducted system is your best choice, the Chiltrix system combined with a FirstCo DC-Inverter powered VMB will be your most efficient choice.\u00a0<a href=\"https:\/\/www.chiltrix.com\/documents\/VMB-Sizing-Guide.pdf\"><u>See Ducted Chiller Fan Coil Sizing Guide<\/u><\/a>\u00a0And see\u00a0<a href=\"https:\/\/www.chiltrix.com\/hydronic-air-handler\/concealed-ceiling-FCU.html\">mini-duct air handler unit<\/a>\u00a0info here.<\/p>\n<h2>About DC Inverter Fan Motor\u00a0Technology<\/h2>\n<table style=\"font-weight: 400;\" width=\"650\">\n<tbody>\n<tr>\n<td width=\"279\">Whether it is used for a compressor, a pump, or a fan motor, DC Inverter motors are well known for being more efficient. They also run cooler, last longer, and produce a much lower sound level.<\/p>\n<p>DC Inverter motors have no actual inverter in them, AC power runs through a rectifier circuit converting it to DC power. The DC power is then pulsed in varying frequencies to rotate the motor. The higher the pulse frequency, the faster the motor turns.<\/p>\n<p>DC inverter motors are not only up to 20-40% more efficient at a given speed, they also provide the ability to efficiently match the motor speed to the real-time demand saving even more energy.<\/td>\n<td width=\"361\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: 400;\">Below is the latent heat rejection table for CXI ductless fan coil units\u00a0based on standard AHRI test condition W44F, 80FdB \/ 67FwB.<\/p>\n<table style=\"font-weight: 400;\" width=\"413\">\n<tbody>\n<tr>\n<td width=\"72\">Model<\/td>\n<td width=\"174\">Moisture\u00a0Removal\u00a0(L\/h)<\/td>\n<td width=\"167\">Sensible\u00a0Heat\u00a0Ratio<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">CXI-34<\/td>\n<td width=\"174\">0.38<\/td>\n<td width=\"167\">74%<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">CXI-65<\/td>\n<td width=\"174\">0.68<\/td>\n<td width=\"167\">75%<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">CXI-85<\/td>\n<td width=\"174\">0.85<\/td>\n<td width=\"167\">77%<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">CXI-120<\/td>\n<td width=\"174\">1.32<\/td>\n<td width=\"167\">74%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: 400;\">\nAbove at max speed.<\/p>\n<table style=\"font-weight: 400;\" width=\"415\">\n<tbody>\n<tr>\n<td width=\"127\"><strong>CXI Fan Speed CFM\u3000<\/strong><\/td>\n<td width=\"72\"><strong>CXI-34<\/strong><\/td>\n<td width=\"72\"><strong>CXI-65<\/strong><\/td>\n<td width=\"72\"><strong>CXI-85<\/strong><\/td>\n<td width=\"72\"><strong>CXI-120<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Air volume(H)<\/strong><\/td>\n<td><strong>94.2<\/strong><\/td>\n<td><strong>188.3<\/strong><\/td>\n<td><strong>270.7<\/strong><\/td>\n<td><strong>341.4<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Air volume(M)<\/strong><\/td>\n<td><strong>64.7<\/strong><\/td>\n<td><strong>129.5<\/strong><\/td>\n<td><strong>194.2<\/strong><\/td>\n<td><strong>241.3<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Air volume(L)<\/strong><\/td>\n<td><strong>53.0<\/strong><\/td>\n<td><strong>107.1<\/strong><\/td>\n<td><strong>158.9<\/strong><\/td>\n<td><strong>200.1<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Placerat tempor dolor eu leo ullamcorper et magnis habitant ultrices consectetur arcu nulla mattis fermentum adipiscing a et bibendum sed platea malesuada eget vestibulum.<\/p>\n","protected":false},"featured_media":15700,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[20],"product_tag":[],"class_list":{"0":"post-323","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-accessories","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product\/323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/comments?post=323"}],"version-history":[{"count":2,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product\/323\/revisions"}],"predecessor-version":[{"id":15701,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product\/323\/revisions\/15701"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/media\/15700"}],"wp:attachment":[{"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/media?parent=323"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product_cat?post=323"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/demo-websitedesigns.com\/chiltrix\/v1\/wp-json\/wp\/v2\/product_tag?post=323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}